Surge Protection and Power Filtering
A12BF - Smart Board B12R - Green Board B8F - Smart Filter 8 C2 - Smart Filter Duo D1/45B Smart Filter E1/45B Smart Protect4 Test ProductPower Conditioning
HA5 - Smart Hum Assassin PS10 - Smart Power Station PS20 - Smart Power StationLaptop/Portable PC's
N1 - Smart Traveler N2/N3 Smart TravellerAV & Computer Server Rack Protection
PS20 - Smart Power Station RF11 – Smart Rack Guard 11 RM10 - Rack Mount BracketHardwired
CM90 - Hardwired DRM95 - Hardwired (20Amp) DRM95 - Hardwired (30Amp)E1/45B Smart Protect4
Price: $109.95
Click picture for larger view
Product Description
FOR TYPICAL USERS AND APPLICATION
Ideal for home office equipment, computers, home theatre components, sewing machines, fridges, washing machines and for users wanting superior AC mains and telephone surge protection due to incoming disturbances whether inner city, suburban, industrial, rural or domestic situations.
Product Dimensions: 85mm(W) x 400mm (L) x 45mm(D)
Features
- 4 OUTLETS
- BROADBAND, PAY TV, ANTENNA & NETWORK
- MAXIMUM FIRE SAFETY - ONLY MANUFACTURED WITH FLAME RETARDENT PLASTICS
- 100% AUSTRALIAN OWNED AND COMPLIANT
- MASSIVE 125,000 AMP, MAXIMUM SPIKES 3670 JOULES
Specfications
| Description | Specification |
|---|---|
| Model No. | E1/45B |
| Supply Voltage | 240/Vac 50/Hz |
| Maximum Current Rating | 10amps/2400 W (Va) |
| Clamping Voltage | 275Vac |
| Reaction Time | Less than 1 Nano Sec |
| Maximum Transient Spike Impulse Current (AMPS) | 125,000 amps. Equivalent to 31,200 Amps using UL1449 standard |
| Maximum Energy Dissipation (Joules) | 3670 Joules.Equivalent to 1240 Joules using UL1449 standard |
| Protection Modes | (all 4 outlets Protects on all 3 conductors) Active/Neutral, Active/Earth, Neutral/Earth |
| Noise Reduction Filter | EMI/RFI |
| Total Number of Protected AC Outlets | 4 |
| Pay TV & "F" Type Connection | 1 x IN - 1 x OUT |
| AV/TV Anntennae Coax Connection | 1 x IN - 1 x OUT |
| RJ 45 Data Protection | 1 x IN - 1 x OUT |
| Earth Potential Rise | Protection |
| Earth leakage Range | Less than 1 milli amp |
| Operating conditions | Indoor / AC Mains |
| Operating Temperatures | - 10C/+60C |
| Cable length | 1.2m |